Results are representative and informational only. Under Texas Instruments' C2000 software license terms, real TI SDK source code is confidential and licensed for internal use only, so no TI code is included, displayed, processed, or emitted here. All C code on this site is synthetic, written for this demo, with invented names and values that resemble typical power-converter firmware. The generated headers compile against this demo's sample firmware in CI; the "legacy" files used for the audit are illustrative and not guaranteed to compile on any target. Product ratings come from public IntelliPower data sheets; all circuit values and gains are invented. Independent demo, not affiliated with or endorsed by AMETEK, IntelliPower, or Texas Instruments. TI, C2000, and Code Composer Studio are trademarks of Texas Instruments.

Magnetics workspace

Set a requirement, compare candidates, and inspect the evidence.

10 real cores · 12 synthetic drawings · 7 need reviewLocal computation · DC-bias screening only

Size an inductor

Candidates are loaded below. Change a requirement and select Size it to compare again.

Screening method and limits

Enter a requirement; every Kool Mµ toroid in the catalog, stacked one to four high, is tried with the fewest turns estimated to reach the inductance at peak current, the smallest wire that meets the current-density limit (fewest strands when within 10%), and a window-fill check. Computed in your browser by the same Python as the checks below. DC-bias screening only: adjusted curves are estimates; AC excitation, losses, and temperature need separate validation.

Candidate designs

Loading the in-browser engine…

Past designs

See what the checks catch, then explore the searchable library. All drawings are synthetic.

DrawingTitleCoreInductance (transformers: Lm min)Current (largest winding)Checks
How it works
  1. Extract. Each drawing's PDF text layer is parsed into fields (core, winding table, electrical table, title block). Every field keeps the text it came from. These drawings share one template; real drawings vary, so the first real step would be sampling about ten of yours to fix the schema, with a vision model and human review for scans.
  2. Check. Textbook physics against vendor data: stated inductance vs AL·N² (within the core's AL tolerance), DC bias on powder cores (peak magnetizing force vs the data sheet's 80%-permeability point), transformer peak flux vs Bsat, turns ratio, current density, and window fill. Anything that fails goes to review with the reason and the math.
  3. Search. Filter checked records, and rank the closest past designs, the question a design engineer actually asks first.
Core catalog · real vendor data
CoreTypeAL (nH/turn²)Ae (mm²)le (mm)Wa (mm²)DC bias at 80% (min)Bsat (min, 100 °C)Source
0077894A7Magnetics Kool Mµ toroid75 ± 8%65.463.515639 Oe—Magnetics 0077894A7 data sheet rev 2/11/2022 p1
0077071A7Magnetics Kool Mµ toroid61 ± 8%65.681.429739 Oe—Magnetics 0077071A7 data sheet rev 10/6/2021 p1
0077548A7Magnetics Kool Mµ toroid127 ± 8%65.681.429714 Oe—Magnetics 0077548A7 data sheet rev 10/6/2021 p1
0077083A7Magnetics Kool Mµ toroid81 ± 8%10798.442739 Oe—Magnetics 0077083A7 data sheet rev 10/6/2021 p1
0077439A7Magnetics Kool Mµ toroid135 ± 8%199107.442739 Oe—Magnetics 0077439A7 data sheet rev 4/21/2025 p1
0077717A7Magnetics Kool Mµ toroid32 ± 8%12512775195 Oe—Magnetics 0077717A7 data sheet rev 10/7/2021 p1
0077110A7Magnetics Kool Mµ toroid75 ± 8%14414394839 Oe—Magnetics 0077110A7 data sheet rev 9/30/2021 p1
0077908A7Magnetics Kool Mµ toroid37 ± 8%221196182095 Oe—Magnetics 0077908A7 data sheet rev 10/7/2021 p1
E32/16/9-3C94Ferroxcube 3C94 E pair2500 ± 25%8374147.84 *—320 mTFerroxcube E32/16/9 product specification 2016 p1-2
E42/21/15-3C94Ferroxcube 3C94 E pair4100 ± 25%17897256.04 *—320 mTFerroxcube E42/21/15 product specification 2016 p1-2

Powder toroids are limited by DC bias (the magnetizing force at which permeability falls to 80%, data sheet minimum); ferrite E cores by saturation flux density. * E-core window derived from nominal dimensions as (B − C)/2 × 2E, before the coil former.

Assumptions, limits, and validation

Drawing checks agree with the blind answer key on 12 of 12 synthetic drawings.